Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577931

RESUMEN

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Complicaciones Posoperatorias , Estudios Prospectivos , Recuperación de la Función , Factores de Riesgo , España , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
J Invasive Cardiol ; 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38517884

RESUMEN

Dynamic road-mapping (DRM) (Dynamic Coronary Roadmap; Philips) offers a real-time, dynamic overlay of the coronary tree on fluoroscopy.

3.
J Invasive Cardiol ; 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38517883

RESUMEN

A 69-year-old man who underwent a liver transplant in 2014 due to hepatitis C virus hepatopathy was evaluated for dyspnea on exertion and chest pain.

4.
J Endovasc Ther ; : 15266028241233994, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38385241

RESUMEN

CLINICAL IMPACT: Mechanical thrombectomy using a thromboaspiration catheter can be an effective alternative in the treatment of subacute pulmonary embolism.

5.
Catheter Cardiovasc Interv ; 103(3): 482-489, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38204382

RESUMEN

OBJECTIVES: The aim of this study was to analyze the efficacy and safety of percutaneous balloon pericardiotomy (PBP) in oncological patients who present with a malignant pericardial effusion (MPE). BACKGROUND: The use of PBP as a treatment for MPE is not standardized due to the limited evidence. Furthermore, the performance of a second PBP for a recurrence after a first procedure is controversial. METHODS: The BALTO Registry (BALloon pericardioTomy in Oncological patients) is a prospective, single-center, observational registry that includes consecutive PBP performed for MPE from October 2007 to February 2022. Clinical and procedural, characteristics, as well as clinical outcome were analyzed. RESULTS: Seventy-six PBP were performed in 61 patients (65% female). Mean age was of 66.4 ± 11.2 years. In 15 cases, a second PBP procedure was performed due to recurrence despite the first PBP. The procedure could be performed effectively in all cases with only two serious complications. Ninety-five percent of cases were discharged alive from the hospital. During a median follow-up of 6.3 months (interquartile range [IQR], 0.9-10.8), MPE recurred in 24.5% cases although no recurrences were reported after the second procedure. No evidence of malignant pleural effusion developed on follow-up. The median overall survival time was 5.8 months (IQR, 0.8-10.2) and the time to recurrence after the first PBP was 2.4 months (IQR, 0.7-4.5). CONCLUSIONS: PBP is a safe and effective treatment for MPE. It could be considered an acceptable therapy in most MPE, even in those who recur after a first procedure.


Asunto(s)
Oclusión con Balón , Derrame Pericárdico , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Pericardiectomía/efectos adversos , Resultado del Tratamiento , Estudios Prospectivos , Derrame Pericárdico/diagnóstico por imagen , Derrame Pericárdico/etiología , Derrame Pericárdico/terapia , Oclusión con Balón/efectos adversos
6.
RMD Open ; 10(1)2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38191213

RESUMEN

BACKGROUND: Systemic lupus erythematosus (SLE) significantly affects the lungs and heart, and pulmonary hypertension (PH) is a severe manifestation that leads to considerable morbidity and mortality. OBJECTIVES: We aimed to determine the prevalence and risk factors of probable SLE-PH, assess the main echocardiographic predictors and develop a potential screening strategy. METHODS: A prospective single-centre study was conducted on 201 patients with SLE who underwent transthoracic echocardiography. Patients meeting PH criteria were referred for right heart catheterisation (RHC). RESULTS: Among patients, 88.56% were women, 85.57% were of Spanish origin and 43.78% had structural heart disease. Out of these, 16 (7.96%) had intermediate or high probability criteria for PH according to European Society of Cardiology (ESC) 2022. Six RHCs confirmed PH with a prevalence of 2.99% for SLE-PH and 1.99% for SLE-pulmonary arterial hypertension (PAH). KEY RISK FACTORS: Key risk factors included age, cardiorespiratory symptoms, serositis, anti-Ro, cardiac biomarkers and altered pulmonary function tests (PFTs). PH was linked to a higher Systemic Lupus International Collaborative Clinics/American College of Rheumatology Damage Index (SDI) (mean SDI 4.75 vs 2.05, p<0.001) and increased mortality risk in a 2-year follow-up (12.50% vs 1.08%, p=0.002). CONCLUSION: In our cohort, 7.96% of patients with SLE had an intermediate or high PH probability. By RHC, six patients (2.99%) met the ESC/European Respiratory Society criteria for PH and four (1.99%) for PAH. The main risk factors were older age, cardiorespiratory symptoms, serositis, anti-Ro, cardiac biomarkers and altered PFTs. PH was a severe SLE complication, suggesting the need for earlier diagnosis through data-driven screening to reduce associated morbidity and mortality.


Asunto(s)
Hipertensión Pulmonar , Lupus Eritematoso Sistémico , Serositis , Humanos , Femenino , Masculino , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/epidemiología , Hipertensión Pulmonar/etiología , Prevalencia , Estudios Prospectivos , Ecocardiografía , Lupus Eritematoso Sistémico/complicaciones , Lupus Eritematoso Sistémico/epidemiología , Biomarcadores
7.
Cardiovasc Revasc Med ; 59: 93-98, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37723011

RESUMEN

INTRODUCTION: Clinical events may occur after percutaneous coronary intervention (PCI), particularly in complex lesions and complex patients. The optimization of PCI result, using pressure guidewire and intracoronary imaging techniques, may reduce the risk of these events. The hypothesis of the present study is that the clinical outcome of patients with indication of PCI and coronary stent implantation that are at high risk of events can be improved with an unrestricted use of intracoronary tools that allow PCI optimization. METHODS AND ANALYSIS: Observational prospective multicenter international study, with a follow-up of 12 months, including 1064 patients treated with a cobalt­chromium everolimus-eluting stent. Inclusion criteria include any of the following: Lesion length > 28 mm; Reference vessel diameter < 2.5 mm or > 4.25 mm; Chronic total occlusion; Bifurcation with side branch ≥2.0 mm;Ostial lesion; Left main lesion; In-stent restenosis; >2 lesions stented in the same vessel; Treatment of >2 vessels; Acute myocardial infarction; Renal insufficiency; Left ventricular ejection fraction <30 %; Staged procedure. The control group will be comprised by a similar number of matched patients included in the "extended risk" cohort of the XIENCE V USA study. The primary endpoint will be the 1-year rate of target lesion failure (TLF) (composite of ischemia-driven TLR, myocardial infarction (MI) related to the target vessel, or cardiac death related to the target vessel). Secondary endpoints will include overall mortality, cardiovascular mortality, acute myocardial infarction, TVR, TLR, target vessel failure, and definitive or probable stent thrombosis at 1 year. IMPLICATIONS: The ongoing OPTI-XIENCE study will contribute to the growing evidence supporting the use of intra-coronary imaging techniques for stent optimization in patients with complex coronary lesions.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Sirolimus , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
8.
Front Cardiovasc Med ; 10: 1199475, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37745092

RESUMEN

Background: Third generation drug-eluting stents (DES) potentially offer better technical performance and reduced neointimal proliferation than previous generation DES. The XLIMIT non-inferiority trial evaluated the performance of the Xlimus (a novel sirolimus-eluting coronary stent system) in terms of endothelialization and tissue healing compared to the bioresorbable polymer Synergy DES. Methods: A total of 177 patients undergoing percutaneous coronary intervention (PCI) were randomized in a 2:1 ratio (2 Xlimus: 1 Synergy). The primary endpoints, defined as the in-stent neointimal volume weighted by the sum of the lengths of the implanted stent (ISNV) and the in-stent neointimal percent volume obstruction (%VO) were evaluated at 6-9 months by means of optical coherence tomography (OCT). Additional OCT parameters as well as clinical endpoints were also collected. Results: Most of the patients were males (77.4%), and the mean age was 64 years. One third of the population had stable angina/silent ischemia. A total of 300 stents (237 lesions) were analyzed: 198 (152 lesions) were in the Xlimus group, and 102 (85 lesions) in the Synergy group. The ISNV in the Xlimus group was 30.7 ± 24.5 mm3 while in the Synergy group it was 26.5 ± 26.7 mm3: the difference between the two means was 0.08 (-0, 04-0, 45), p = 0.018, thus meeting the non-inferiority hypothesis. The %VO was 16.3% ± 10.4% and 13.3% ± 10.8% in the Xlimus and Synergy groups, respectively: the difference between the two means was 3.0 (-0, 06-4, 2), (p = 0.01), thus meeting the non-inferiority hypothesis. No difference was found with respect to the secondary OCT endpoints as well as for clinical endpoints. Conclusions: The study results confirm that the biological interaction of the Xlimus and Synergy DES with the coronary artery is comparable, and that translates in very reassuring OCT parameters at follow-up: as such, the Xlimus is non-inferior to the Synergy. Clinical Trial Registration: ClinicalTrials.gov, identifier (NCT03745053).

9.
Microvasc Res ; 150: 104598, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37633337

RESUMEN

In the 20th century, research focused on cholesterol and lipoproteins as the key mechanism in establishing atherosclerotic cardiovascular disease (ASCVD). Given that some studies demonstrated subclinical atherosclerosis in subjects without conventional cardiovascular risk factors, the elevated low-density lipoprotein (LDL) levels alone cannot account for the entire burden of atherosclerosis. Hence, large-scale clinical trials demonstrated the operation of immune and inflammatory pathways in ASCVD. In this regard, the evidence establishes that cells of the immune system, both the innate (neutrophils, macrophages) and adaptive (T cell and other lymphocytes) limbs, contribute to atherosclerosis and atherothrombosis. Besides, basic science studies have identified proatherogenic cytokines such as interleukin (IL)-1, IL-12, and IL-18. In this regard, some studies showed that antiinflammatory therapy targeting the immune system by modulating or blocking interleukins, also known as anti-cytokine therapy, can reduce the risk of major cardiovascular adverse events. The neutrophils play a key role in the innate immune system, representing the acute phase of an inflammatory response. In contrast, lymphocytes represent the adaptive immune system and promote the induction of autoimmune inflammation, especially in the chronic inflammatory response. Through the literature review, we will highlight the inflammatory pathway for the physiopathology of ASCVD, HF, and COVID-19. In this regard, the neutrophil-to-lymphocyte ratio (NLR) integrates the innate immune and adaptive immune systems, making the NLR a biomarker of inflammation. In addition, we provided an update on the evidence showing that high NLR is associated with worse prognosis in heart failure (HF), ASCVD, and COVID-19, as well as their clinical applications showing that the normalization of NLR after anti-cytokine therapy is a potential predictor of therapy responsiveness and is associated with reduction of major adverse cardiovascular events.


Asunto(s)
Aterosclerosis , COVID-19 , Enfermedades Cardiovasculares , Insuficiencia Cardíaca , Humanos , Enfermedades Cardiovasculares/diagnóstico , Neutrófilos , Pronóstico , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/tratamiento farmacológico , Linfocitos , Biomarcadores , Enfermedad Crónica
11.
Eur Heart J Acute Cardiovasc Care ; 12(5): 299-305, 2023 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-37010101

RESUMEN

AIMS: Spontaneous coronary artery dissection (SCAD) is a relatively infrequent cause of acute coronary syndrome. Clinical features, angiographic findings, management, and outcomes of SCAD patients who present reduced left ventricular ejection fraction (LVEF) remain unknown. METHODS AND RESULTS: The Spanish multicentre prospective SCAD registry (NCT03607981), included 389 consecutive patients with SCAD. In 348 of these patients, LVEF could be assessed by echocardiography during the index admission. Characteristics and outcomes of patients with preserved LVEF (LVEF ≥50%, n = 295, 85%) were compared with those with reduced LVEF (LVEF <50%, n = 53, 15%). Mean age was 54 years and 90% of patients in both groups were women. The most frequent clinical presentation in patients with reduced LVEF was ST-segment elevation myocardial infarction (STEMI) (62% vs. 36%, P < 0.001), especially anterior STEMI. Proximal coronary segment and multi-segment involvement were also significantly more frequent in these patients. No differences were found on initial revascularization between groups. Patients with reduced LVEF significantly received more often neurohormonal antagonist therapy, and less frequently aspirin. In-hospital events were more frequent in these patients (13% vs. 5%, P = 0.01), with higher rates of death, cardiogenic shock, ventricular arrhythmia, and stroke. During a median follow-up of 28 months, the occurrence of a combined adverse event did not statistically differ between the two groups (19% vs. 12%, P = 0.13). However, patients with reduced LVEF had higher mortality (9% vs. 0.7%, P < 0.001) and readmission rates for heart failure (HF) (4% vs. 0.3%, P = 0.01). CONCLUSION: Patients with SCAD and reduced LVEF show differences in clinical characteristics and angiographic findings compared with SCAD patients with preserved LVEF. Although these patients receive specific medications at discharge, they had higher mortality and readmission rates for HF during follow-up.


Asunto(s)
Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Disfunción Ventricular Izquierda , Humanos , Femenino , Persona de Mediana Edad , Masculino , Pronóstico , Función Ventricular Izquierda , Volumen Sistólico , Infarto del Miocardio con Elevación del ST/complicaciones , Infarto del Miocardio con Elevación del ST/diagnóstico , Vasos Coronarios , Estudios Prospectivos , Intervención Coronaria Percutánea/métodos , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/etiología , Angiografía Coronaria
12.
J Invasive Cardiol ; 35(4): E223-E224, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-37029998

RESUMEN

Cardiac computed tomography (CT) scan was performed in a 69-year-old male with atrial fibrillation radiofrequency ablation who was admitted for transcatheter angioplasty of left inferior pulmonary vein (LIPV) stenosis due to recurrent hemoptysis. CT showed complete ostial occlusion in the area of the LIPV. Occlusion of the pulmonary vein ostium is a rare complication. We describe the successful use of chronic occlusion techniques in the treatment of this patient.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Enfermedades Vasculares , Masculino , Humanos , Anciano , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Angioplastia/efectos adversos , Enfermedades Vasculares/cirugía , Constricción Patológica/diagnóstico , Constricción Patológica/etiología , Constricción Patológica/cirugía , Ablación por Catéter/efectos adversos
15.
J Invasive Cardiol ; 35(2): E103-E105, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36735872

RESUMEN

To the best of our knowledge, this case represents the first patient with Mitraclip, Amplatzer, and TricValve devices with a profound clinical improvement and long-term follow-up. In addition, this case illustrates how the treatment of high-risk patients with polyvalvular disease has changed in the last few years.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento
16.
J Invasive Cardiol ; 35(2): E110-E111, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36735875

RESUMEN

An 86-year-old patient with non-valvular atrial fibrillation was referred to our institution to undergo a left atrial appendage (LAA) closure for recurrent gastrointestinal bleeding on direct oral anticoagulants. The transesophageal echocardiogram (TEE) performed the previous day evaluated the morphology and dimensions of the LAA and ruled out any thrombus. During the procedure, a pigtail catheter was inserted into the LAA, observing an unusual image we describe as a culde- sac, without an anomalous connection with any drainage in other vessel or cavity. After additional imaging studies, we concluded that it was morphology related to LAA, which we have termed the "water-gun" morphology. Four morphologies have been described based on the shape of the central and secondary lobes. To the best of our knowledge, this is the first description of a fifth type, which was shown to be effectively closed with current closure devices.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Trombosis , Humanos , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ecocardiografía Transesofágica , Resultado del Tratamiento
19.
Coron Artery Dis ; 33(8): 609-617, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36238983

RESUMEN

BACKGROUND: Treatment of in-stent restenosis (ISR) remains a significant challenge. Current options include repeat stenting or drug-coated balloons. However, there is a paucity of data regarding vascular healing after these strategies. We, aimed to compare optical coherence tomography (OCT)-based vessel healing after treatment with paclitaxel-coated balloons (PCB) or everolimus-eluting stents (EES). METHODS: An OCT substudy (baseline and 6-9 months) of patients from RIBS IV and RIBS V, two prospective multicenter, randomized controlled clinical trials comparing PCB vs. EES in patients with ISR was performed. RESULTS: Sixty-four patients were included (30 PCB and 34 EES). There were no differences in the baseline or angiographic characteristics between groups. Both groups had the same proportion of drug-eluting and bare-metal stent (BMS) ISR. Baseline OCT analysis did not show differences in the qualitative characteristics of the ISR nor the restenotic tissue burden. Follow-up OCT showed a larger mean lumen area in the EES group (6.03 ± 1.5 vs. 5.24 ± 1.3 mm 2 ; P = 0.043) but no difference in angiographic restenosis ( P = 0.66). Percentage tissue coverage was higher with PCB vs. EES (26 ± 13 vs. 19 ± 11%; P = 0.031). EES-treated ISR more frequently had uncovered struts at follow-up [21 (72%) vs. 12 (44%); P = 0.034]. Tissue covering struts more frequently had a high backscatter structure after PCB [21 (78%) vs. 16 (55%); P = 0.07]. CONCLUSIONS: Compared with EES, ISR treated with PCB demonstrated more strut coverage with mainly high backscattering tissue. Larger OCT-defined neointimal proliferation in PCB-treated ISR did not translate into higher angiographic restenosis rates.


Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria , Stents Liberadores de Fármacos , Humanos , Everolimus , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Paclitaxel , Tomografía de Coherencia Óptica , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Estudios Prospectivos , Angiografía Coronaria , Metales , Resultado del Tratamiento , Stents , Constricción Patológica/tratamiento farmacológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...